This test aims to determine air permeability, water tightness, and wind pressure resistance of windows and glazed doors regardless of the materials used (wood, aluminum, PVC, mixed, etc.).
This test aims to determine air permeability, water resistance, and wind pressure resistance of aluminum curtain walls.
This test aims to determine damage resulting from the impact of a soft and heavy body on a closed door leaf fixed within its frame.
This test aims to determine the permanent deformation resulting from the application of a vertical load on an open door leaf fixed within its frame.
This test aims to determine the opening and closing forces of hinged or sliding doors, as well as the operating forces of locks and handles.
This test aims to determine the water tightness resistance of installed façades by spraying a specified quantity of water (5 L/min/m ±10%) for 30 minutes, ensuring no leakage occurs.
This test aims to evaluate the behavior of guardrails when subjected to static and dynamic loads.